AHDU-1460
AHDU-1460
  • Ultimate Authentication Performance
  • PoE and 3rd Party Integration 
  • Threat Levels and Port Failover
  • Advanced Access Control Functions
  • Supervised and Programmable Inputs

ULTIMATE AUTHENTICATION PERFORMANCE

Supports up to 400,000 (1:N) RFID card / mobile credential, 400,000 (1:1) & 50,000 (1:N) fingerprint, 100,000 (1:1) & 5,000 (1:N) facial, 5,000 (1:N) & 10,000 (1:1) palm authentication in one single controller.  

Advanced Access Control Functions

The controller supports advanced access control functions such as multi-frequency RFID card support, multi-biometric authentication support, mobile credential support, anti-passback, multi-level authentication, and cross-panel linkage (global linkage). 

 

PORT FAILOVER (TCP/IP COMING SOON) & REDUNDANCY

The AHDU controller series has dual ethernet ports. If the primary communication port fails, it will then switch to the secondary port automatically (the controller supports separate network configurations for both ports). 100Base-TX Ethernet data transfer is included on the AHDU controller. 100Base-TX communication between the AHDU security core allows users to take full advantage of high-speed network technology.
The AHDU controller series has 3 RS-485 ports on the board, which support the redundancy function dedicated to ports 2 & 3. If one of the RS-485 connections experiences problems, the other port will activate automatically to avoid disconnection.

 

DUAL SYSTEM ROM PROTECTION DESIGN

To offer the best operation stability, durability, and safety and tackle different kinds of situations, such as an improper upgrade, cyber attack, and malware infections that completely render the ROM to inoperable status.  Armatura's controllers are built with a dual ROM design, one of the ROMs acts as a primary ROM for the system startup, and the second layer ROM acts as a "Recover" ROM. When the primary ROM happens to fail or malfunction, the second layer ROM will automatically take over on your next controller board startup.

 

CYBER SECURITY

Advanced Encryption Standard (AES) 256-bit algorithm for communication with Explorer series readers and I/O expansion boards through TCP/IP; AES 128-bit encryption to the readers and I/O expansion boards through OSDP V2.2 over RS-485.
AES128 / TLS 1.2 (with AES256) communication between Armatura One server and edge devices.
Communications between the Armatura One server and web-client are protected by HTTPS / TLS1.2 (AES256) or above
Enhanced cybersecurity level is provided by an additional crypto chip (Certified EAL6+ standard), providing dedicated storage and cryptographic functionality for the AHSC-1000 controller.
Supports IP/Mac address filtering functions, and VLAN isolation to enhance cybersecurity standards.

GENERAL INFORMATION

 
Primary Power PoE 802.3at/af / 9 - 24 VDC ± 20%, 550 mA maximum (reader current not included)
Primary Host Communication Ethernet: 100Base-TX
256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications
Secondary Host Communication BLE 5.2
Third Host Communication Wi-Fi IEEE 802.11ac 5GHz , or 2.4GHz/5GHz IEEE 802.11n
256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications
Ethernet network connection Port 1:Ethernet: 100Base-TX
Port 2: Ethernet: 100Base-TX
(Configurable for Port Failover)
RS-485 connection Port 1: Armatura RS-485 / OSDP V2.2
Port 2: Armatura RS-485 / OSDP V2.2
Port 3: Armatura RS-485 / OSDP V2.2
(Configurable for Port Redundancy dedicated on port 2 & 3)
Number of Ports 2*TCP/IP
3*RS-485
4*Wiegand
Inputs 4-state supervision, resistor values (5% tolerance),
Normally open contact: use 1.2k, 2.2k. 4.7k or 10k/
Normally closed contact: use 1.2k, 2.2k. 4.7k or 10k/
Dedicated Panel Tamper IO Input*
Dedicated Microchip Control Fire Alarm IO Input & REX Input for catastrophic situation
Outputs 4 relay,
4* Form-C with dry contacts
Normally Open Contact Rating 5A @ 30Vdc resistive
Normally Closed Contact Rating 5A @ 30Vdc resistive
On-Board Monitor Size: 2.4", Resolution: 320*240, TFT Monitor
Quickly view status of board, connected doors and for configuration information display
On-Board Webserver Webserver for System Configuration and Management
Dashboard for Controller Status Monitoring,
Device Connection Status Monitoring & Configuration, Performance Status,
server Primary Controller Setting, Network Status Monitoring & Setting,
IP Access Filter, SSL / TLS Certificates Setting,
Access Log Export, Controller Reset, Debug Status Monitoring,
Operation Log Monitoring, User Management,
Date & Time Setting, Daylight Saving Time Setting,
NTP server Setting, General Status, Controller Information
RFID Card Capacity 400,000 (1:N) / 800,000 (1:1)
Maximum RFID Card Number Length Supports up to 512bits card number length
Mobile Credential Capacity 400,000 (1:N) (Bluetooth)
400,000 (1:N) (NFC)
400,000 (1:N) (Dynamic QR Code)
Fingerprint Capacity 50,000 (1:N) / 100,000 (1:1)
Face Capacity 5,000 (1:N) / 100,000 (1:1)
Palm Capacity 3,000 (1:N) / 5,000 (1:1)
Transaction Buffer 5,000,000 Events
Access Level 100,000 Levels
On-Board Access Point Control 4 access point on board
On-Board Reader Support 3 (OSDP over RS-485) or 4 (Wiegand) with on-board IO
Maximum Access Point 4
Maximum Readers 8
Maximum Inputs 384 (using Armatura AHEB-1602)
Maximum Outputs 385 (using Armatura AHEB-0216)
Maximum IO Board 24pcs (3*High Speed RS-485 communication)

RFID / BIOMETRICS READER INTERFACE

Input Voltage 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader
Maximum Input Current 12 - 24 Vdc +/- 10% regulated, 500 mA maximum each reader
RS-485 Protocol AES-128, OSDP Secure Channel
OSDP Mode 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
3rd Party reader: support OSDP V2.2 or above
Wiegand Read: support up to 128 bits / Write: Support 26 / 34 / 37 bit, and other customised card formats

Tamper Input (Wiegand)

TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
Buzzer Output (Wiegand) TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
LED Output (Wiegand) TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum
Data Inputs RS-485, OSDP and Wiegand standards supported.
Maximum RS-485 /OSDP cable length: 3937ft. (1200m)
Maximum Wiegand cable length: 328ft (100m)

IO EXPANSION BOARD INTERFACE

RS-485 Protocol AES-128, OSDP V2 Secure Channel
OSDP Mode 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit. Maximum cable length: 2,000 ft. (609.6m)
Data Inputs OSDP and Wiegand standards supported.
Maximum cable length: 500 ft. (152m)

CABLE REQUIREMENT

Power & Relays One twisted pair, 18 to 16 AWG
Ethernet CAT-5, minimum 330 ft. (100m)
Ethernet Failover Port CAT-5, minimum 330 ft. (100m)
RS-485 Reader Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
RS-485 I/O Device Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
RS-485 Failover Port 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit.
One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
Wiegand Port 20 AWG shielded Wiegand wire, 328ft. (100m)

MECHANICAL

 
Dimensions 4.8” W x 10.2” L x 2.5” H (122 x 260 x 62.5mm)
Weight 30oz (830g)
DIN Rail Mounting Supported DIN35 Rail
Compatible with UTA89 Din Rail Adapter for screwing on switchgear (Sold Separately)
Wall mount
Housing Material ABS-PC UL-94 V2

ENVIRONMENTAL

 
Operating Temperature -22°F ~ 158°F (-30°C~70°C), Operating & Storage
Operating Humidity 0-95% RHNC
Certification(s)* CE, FCC, UL, RoHS, UL294 Certification(s)
Security Rating Secure Data Storage in EAL 5+ Certified Crypto Chip

SOFTWARE INTERFACE

TCP/IP Mode Ethernet: 100Base-TX
TCP/IP Protocol NTP, SNMP V2 /V3, 802.1X, VLAN, SSH, MQTT, IPv4, IPv6, DNS, DDNS
TCP/IP Encryption Complies with TLS1.2, AES-256 end to end secure communication channel
TCP/IP Communication TCP/IP Communication
Supported Software Armatura One Security System

ARMATURA_Armatura ID UM_EN v1.3_20221031

6.19 Mb User Manual
2022-12-16

ARMATURA_Armatura CONNECT UM_EN v1.3_20221031

5.78 Mb User Manual
2022-12-16

ARMATURA_Armatura Horizon Controller UM_EN v1.5_20221214

13.21 Mb User Manual
2022-12-15

AHDU Series_Leaflet_17May2023

0.4 Mb Data Sheet
2023-05-17